Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13629359

- Product Categories
- Friendly Links
- home > Supply > Taiyuan gas boiler burners, sun energy and environmental protection (certified), boiler burners
Information Name: | Taiyuan gas boiler burners, sun energy and environmental protection (certified), boiler burners |
Published: | 2014-12-17 |
Validity: | 0 |
Specifications: | Limited |
Quantity: | |
Price Description: | |
Detailed Product Description: | Taiyuan gas boiler burners, sun energy and environmental protection (certified), boiler burners can be provided by the Environmental Protection Equipment Co., Ltd. Shanxi sun. Shanxi Environmental Protection Equipment Co., Ltd. Rising Sun (www.sxxrn.com) is specialized in the "boiler, biomass boilers, boiler burner, methanol burner" of the enterprise, the company of "honesty, hard service" concept, to provide you with The most high-quality products and services. Welcome to inquire! Contact: Zhang. Countermeasures burner burning: ensure the correct use of the furnace shutdown garden design cut chance, check the burner installation angle Taiyuan industrial boiler burners ensure proper furnace design inscribed circle. Well the 2nd furnace once cold wind, cold damper characteristic test hot mix thoroughly test and secondary air, to ensure the central furnace flame is not skewed. 1. Run strengthen operational control staff should be adjusted to grasp the changes of coal into the furnace, according to the coal quality analysis report, adjusted to run good milling system to ensure coal fineness in the optimal range. 2. Staff should always observe the boiler operation of fire pulverized coal, pulverized coal fire control isolation between the primary air vents exports about 500 ~ 800 mm. According pulverized coal concentration, preheat the burner wall temperature timely adjust the opening of the door of qi. 3. Run the staff at the high and low load conditions, the combustion should be adjusted, adjust the primary air, secondary air ratio, to ensure that the flame does not skew the furnace. Shanxi Environmental Protection Equipment Co., Ltd. Rising Sun burner start operation: (1) the installation of a new furnace, gas detection should carefully before commissioning meets the requirements of the burner; check supply line detection equipment is normal and pipeline valve opening and closing is normal, easy to use in the future if and maintenance. (2) the newly installed pipeline, should carefully check the reliability and piping installation of all piping tightness. (3) the use of a separate user gasification station, to ensure gas supply, gas combustion parameters meet the safety requirements. (4) The operator carefully read the manual of the equipment, knowledge and proficiency in the safe operation of the method. (5) Before each turn to check the gas valve is open, otherwise the burner does not work. Power control cabinet and on the burner (6) start control button, then the DRO will display the current temperature in the furnace, the furnace temperature is mounted Xin'an ambient temperature. (7) to start the fan control button, fan mounted on the furnace to work at this time if the fan control cabinet damage protection does not automatically enter the next step. (8) The combustion air blower work without anomalies boiler burners, combustion control button and then start, then began to work combustion process controller Taiyuan biogas boiler burner, it goes through certain procedures before the purge, ignition, aspirated, flame detection, and other security programs and ultimately burn. (9) When the burner is not conducive to the combustion controller receives a signal (for example: ignition failure, pressure instability, the circuit in question) when other issues, immediately turn off the gas burner controller and an alarm signal. (10) If the burner control alarm Taiyuan Environmental boiler burners must be after troubleshooting before they can continue their work by the operator manually reset. Operation (11) the entire device, the operator should refer to the furnace safety procedures and requirements to operate the production process. (12) needs to be adjusted according to the requirements of the production process to control the temperature, the operator should refer to the instructions for adjusting intelligent CNC table. |
Admin>>>
You are the 31634 visitor
Copyright © GuangDong ICP No. 10089450, Shanxi Environmental Protection Equipment Co., Ltd. Rising Sun All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 31634 visitor
Copyright © GuangDong ICP No. 10089450, Shanxi Environmental Protection Equipment Co., Ltd. Rising Sun All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility